Non-foodTools & advice

Monitoring
& Validation

Make visible what happens inside your packaging. With humidity indicators, temperature recorders and practical advice for your own measurements and assessment.

  • Visual humidity check
  • Temperature recording
  • Personal advice
Insight into your packaging

Protect.
And know what is happening.

A humidity indicator gives a visual signal. A data logger records measured values over time. This gives you insight into the conditions during storage and transport and lets you assess and adjust in a more targeted way.

DDC supplies humidity indicators and single-use data loggers and thinks along about your measurement question. You collect and assess the information within your own process. We help you choose which tools and product data fit.

Start with what you want to know
01

Visual signal

Humidity indicator cards with a colour change from brown to azure blue.

02

Progression over time

Single-use data loggers record measured values during transport and storage.

03

Your own assessment

You set the requirements and assess the outcome within your own process.

04

Tailored together

We think along about your measurement question and the suitable tools.

Your measurement question

What do you want to know
about your packaging?

Humidity indicator

Do you want to see during a check how the relative humidity relates to the points on the card? A humidity indicator gives a visual signal.

View the cards

Data logger

Do you want to know when a change occurs and how long it lasts? A suitable logger can record measured values over time.

View the three loggers

Your packaging assessment

Do you want to compare two packagings or quantities of desiccant? Define beforehand what you want to demonstrate and which requirements the outcome must meet.

View the approach

A visual signal, a series of measurements or a comparison between packagings calls for a different approach. Tell us your measurement question

Humidity indicators & data loggers

See what happens.
Record what changes.

Two cobalt-free humidity indicator cards and three single-use data loggers. RH stands for relative humidity; an indication point is not a continuous digital measurement.

Humidity indicator cardsCobalt-free
VersionIndication pointsColour changePackaging
Humidity indicator 30–50% RHHIC00430 / 40 / 50% RHBrown → azure blue250 pcs., airtight
Humidity indicator 10–60% RHHIC00510 / 20 / 30 / 40 / 50 / 60% RHBrown → azure blue250 pcs., airtight
Single-use data loggersSingle use
VersionTemperature rangeMax. period of useRecording
GKLog T KTRTemperature−30 to +60 °CUp to 6 monthsTemperature
GKLog Frozen T KTRLow temperatures−40 to +60 °CUp to 3 monthsTemperature
GKLog T&H KTRTemperature & humidity−30 to +60 °CUp to 6 monthsTemperature, humidity and light

Need smaller quantities? Order directly via silica-gel-shop.nl ↗

Unsure which measuring tool fits?

We are happy to look at it with you. Get in touch with us ↗
Tools for your validation

From observation
to substantiation.

Do you want to assess whether your packaging solution meets your requirements? Make clear beforehand what you want to demonstrate and how you assess the outcome.

01Define your goalWhich condition is critical for your product?

Define your limit values, desired protection period and assessment criteria beforehand.

02Define the measurement setupWhich measuring tool, which placement and which measuring moments?

For a logger, also note the interval, the measuring duration and the calibration status.

03Compare carefullyHow do you compare the existing and the modified packaging?

Assess both under comparable conditions and record which materials and quantities you use.

04Assess & documentHow do you store and assess the outcome?

Keep observations, measurement data and deviations. Have the outcome assessed according to your own quality requirements and record your decision.

These four steps help you define the measurement question and approach. A practical starting point for your own assessment and the conversation with DDC.

Request the checklist

Three ways to measure.

Check visually

Humidity indicator card

One colour point per relative humidity, without a timeline. For a check when opening the packaging.

View the cards
Record temperature

GKLog T & Frozen T

Records the temperature progression of a shipment. The Frozen version measures down to −40 °C.

View the loggers
Temperature & humidity

GKLog T&H KTR

Also records humidity and light, for example to see a possible opening of the packaging.

View the logger
Reading & use

A small card.
A deliberate check.

The position of the card and the moment of reading determine which information you get. Agree beforehand how you will check.

Humidity indicator card 30 to 50% RH with brown and blue-coloured indication points
HIC004 · 3 indication points

Humidity indicator 30–50% RH

For visual checking around 30, 40 and 50% relative humidity. The points change colour from brown to azure blue.

  • Indication points at 30 / 40 / 50% RH
  • Cobalt-free
  • 250 pieces, packed airtight
View the card in the overview
Humidity indicator card 10 to 60% RH with brown and blue-coloured indication points
HIC005 · 6 indication points

Humidity indicator 10–60% RH

For visual checking with six indication points over a wider range, in steps of 10% RH.

  • Indication points from 10 up to and including 60% RH
  • Cobalt-free
  • 250 pieces, packed airtight
View the card in the overview

Practical tip for use: place the card in the packaging whose humidity condition you want to follow and avoid direct metal contact. Take cards out of the airtight packaging only at the time of use and read them according to the instructions for your version. Record the date, card type and observation.

What does a colour change mean for your product? That follows from your own quality requirements. Use the card as a signal to assess your packaging and product; a colour alone does not determine whether a product may be released.

Measuring & recording

Follow the progression?
Start with a measurement plan.

A card does not give a timeline. For temperature or humidity during storage or transport, a suitable data logger may be needed.

What needs to be measured?
Relative humidity, temperature or both? Choose measuring range, accuracy and resolution based on the question you want to answer.
Where and for how long?
The position of the sensor, the recording interval and the measuring duration determine what is recorded. Include transport, transshipment and storage as well.
How do you use the data?
Determine how you read out, store data and assess deviations. Check which calibration data are needed for your application.

Single-use data loggers

The three GKLog models are read out after use and automatically deliver a report.

USBread-out
PDFautomatic report
8,000data points

Match the recording interval and the measuring duration to your transport or storage. Request the current specifications, including accuracy and calibration data, from the DDC team.

Your assessment

You set the requirements.
We think along.

DDC supplies tools and advice for your own measurements and packaging assessment. You carry out the measurements and assess the outcome within your own quality process; the automatic report is generated by the logger.

Do you want to record a check on receipt or the progression during an entire journey? Describe the situation and we will help you choose between the versions and think along about measuring range, interval and placement.

Discuss your measurement question
Frequently asked questions

Good to know in advance

What does ‘validation’ mean on this page?→
This concerns tools and advice with which you can substantiate the performance of your packaging. You set the requirements and carry out the measurements and assessment within your own process. DDC helps with the choice of tools and the points of attention. DDC does not offer its own validation service or formal approval.
Does a humidity indicator card also absorb moisture?→
The function of the card is to signal relative humidity. Do not use it as a desiccant. For moisture protection you choose a suitable desiccant and suitable packaging; with the indicator you check the conditions.
Do I choose 30–50% or 10–60% RH?→
Look at which indication points match your product requirements. The 30–50% card has points at 30, 40 and 50% RH. The 10–60% card gives six points, in steps of 10%. A wider range is not automatically more accurate. Request the current specification for tolerances and reading conditions.
Can I see when a limit has been exceeded?→
A humidity indicator card does not give times or a complete progression. If you want to know when a change occurred and how long it lasted, a measuring tool that records data over time is needed. Also check whether the chosen recording interval suits the changes you want to capture.
Does a good reading prove that my product is fine?→
The reading says something about the humidity condition at the location of the card, according to the reading instructions. Product quality can also depend on other factors. Therefore combine the information with your own product requirements, inspections and assessment criteria.
Can I use the cards with food or pharma?→
Assess the placement and possible product contact per application. The cards shown here are not offered as approved for food contact. For an application with additional requirements, the DDC team helps you gather the necessary product information.
How do I read out the GKLog data loggers?→
Connect the logger to a USB port on your computer. The three models automatically generate a PDF report with the stored measurement data. The manufacturer also offers software for further analysis. The report comes from the logger; you assess the data within your own quality process.
Are the GKLog models intended for reuse?→
The GKLog T KTR, Frozen T KTR and T&H KTR shown here are single-use versions: intended for one-time use. Match the logger and the settings beforehand to the duration and conditions of your shipment.
What information helps with measurement advice?→
Tell us what you pack, which condition you want to follow and over which period. State which limit values apply, how you want to read out and where the measurement takes place. With the four steps of your measurement plan you put the most important data in order.