High-Tech & ElectronicsProduct · Packaging · Process

High-Tech &
Electronics

Your components call for careful protection. We help you control moisture and make conditions transparent, from packing to storage and transport.

  • Desiccants & indicators
  • Targeted product advice
  • Short lines of communication
Precision calls for attention

A sensitive product.
A well-considered
package.

A circuit board, optical instrument or technical part has its own requirements for storage and transport. Moisture control starts with those requirements and with the packaging that surrounds the product.

We therefore look at product, material, closure and duration of use. Then together we choose a direction for the desiccant and any monitoring, with product information for your own assessment.

How the components work together
Recognise your application

From component
to complete instrument.

The desired moisture condition and the way of use differ. These three situations are a starting point for the conversation.

Components & assembly

Circuit boards & electronics

From loose components to assembled modules: match moisture control to the requirements of the product and the next step in your process.

What counts?

Component information, packaging barrier and exposure after opening.

Precision equipment

Optics & instruments

For sensitive surfaces and precise equipment, the casing of the desiccant and the placement in the packaging also count.

What counts?

Desired moisture condition, cleanliness and material contact.

From stock to destination

Storage & transport

A spare part in the warehouse or a system en route: the duration, temperature changes and the opening of the packaging partly determine the load.

What counts?

Expected conditions, storage duration and repacking in between.

Suitable solutions

Absorbing moisture.
Making conditions visible.

Desiccants, indicators and loggers each have their own function. We match the version to your packaging and the question you want to answer.

Silica Gel Paper
Absorbing moisture

Silica Gel Paper

Silica gel in a water-vapour-permeable sachet. For moisture control around electronics, optics and instruments in their packaging, among other things.

Match weight, size and casing to the moisture load and your requirements for cleanliness.

View Silica Gel Paper ↗
Silica Gel Tyvek
Absorbing moisture

Silica Gel Tyvek

A flexible desiccant sachet, loose or on a roll. A version to consider when casing and processing are important selection criteria.

Assess the material properties, placement and fit with your packaging process.

View Silica Gel Tyvek ↗
Humidity indicator cards
Making moisture visible

Humidity indicator cards

A colour indication of the relative humidity at the card. The pictured HIC005 has indication points from 10 to 60% RH.

Choose the points that match your acceptance limits. A limit below 10% RH cannot be read with this card.

View this humidity indicator ↗
Temperature & humidity loggers
Recording conditions

Temperature & humidity loggers

The single-use GKLog T&H KTR records temperature and humidity. Afterwards you read out the data via USB as an automatic PDF report.

Determine the measurement location, duration of use and suitable measuring range beforehand.

Discuss your measurement question ↗

You don't need to know yet which product you need. A description or photo of your packaging is a good start.

Ask the DDC team ↗
The complete package

Three components.
One coherent choice.

Circuit board under optical inspection equipment
From component to assembly: the product requirements remain the starting point.
Which data help with the choice?
  1. 01

    A suitable moisture barrier

    Material and closure limit the supply of water vapour. The required barrier follows from your product, environment and storage time.

  2. 02

    A matched desiccant

    Choose capacity, casing and size to suit the total moisture load and the available space in the packaging.

  3. 03

    An agreed check

    Determine what you want to check, where you measure and which limits apply. Then choose a suitable indicator or logger.

The right choice

From technical requirement
to practical implementation.

You know your product and process. With these four topics we make the packaging question concrete and decide the next step together.

Your product & requirements

What do you pack and which conditions are desired? Share component information, any moisture sensitivity classification and requirements for cleanliness or material contact.

Packaging & closure

Provide material, volume, available space and closure method. The resistance of the packaging to water vapour is part of the choice.

Time & environment

How long do storage or transport last? Include temperature, humidity and opening or repacking along the route.

Placement & control

Discuss how the desiccant is added and where you measure. Determine beforehand how you assess the packaging and any indicator.

DEEPEN YOUR KNOWLEDGE

Moisture control and ESD: two functions to align.

Read why a desiccant is not the same as ESD protection.

DEEPEN YOUR KNOWLEDGE

What changes after opening a component package?

Read why the manufacturer's instructions remain leading.

Product information & documentation

Information with which
you can continue.

State which version you are assessing and which requirements you have. We agree which current data and instructions are available.

Related

Solutions, products and examples for this sector.

Frequently asked questions

Good to know
about your electronics packaging.

How much desiccant do we need?→
That follows from the desired moisture condition, initial moisture, product and packaging materials, water vapour permeability, closure, environment and duration of use. The volume of the packaging alone is not enough. Share those starting points for targeted product advice.
Is an ESD package also sufficiently moisture-resistant?→
You cannot derive that from the ESD marking alone. Ask about the properties of the packaging material and the closure. Match the protection against electrostatic discharge and the barrier against water vapour to your components.
Which humidity indicator card suits our components?→
The indication points must match your acceptance limits and the instructions for the component. The pictured HIC005 starts at 10% RH. If you need lower indication points or a specific standard version, put that requirement to us beforehand; do not assume general suitability.
Does the humidity indicator show how much capacity is left?→
No. A humidity indicator card gives a colour indication of the relative humidity at the card. You cannot read the exact remaining absorption capacity of the desiccant with it. The card is also not a record of the complete progression during storage or transport.
What is the difference between an indicator and a logger?→
An indicator gives a visual indication at the card; a logger records measured values over time. Choose a tool to suit the question you want to answer. A logger outside a closed package does not automatically describe the conditions inside that package.
Can you validate the packaging for us?→
DDC supplies tools, product information and advice. We do not offer our own validation service. You assess the complete packaging combination and the measurement results within your own quality process.
High-tech & electronics

Moisture control and ESD: two functions to align.

A desiccant absorbs water vapour. ESD protection concerns electrostatic discharge. A moisture-absorbing sachet does not in itself make a package suitable for ESD-sensitive parts.

Check the properties of the complete packaging combination. A package labelled as antistatic does not automatically have the required barrier against water vapour. Match material and way of working to the requirements of your components.

A question about your situation? Email us
High-tech & electronics

What changes after opening a component package?

After opening, components are exposed to the environment. For moisture-sensitive components, the manufacturer's instructions, including any MSL classification, are the starting point for further processing.

Adding a desiccant or closing the package again does not automatically mean the permitted exposure time starts over. For storage, repacking and any drying treatment, follow the instructions for the specific component.

A question about your situation? Email us